3
AGB Series Vertical Housings
(For Facet AGB series
air/gas coalescer and separator cartridges)
 The
Facet 3 AGB Series vertical housing permits easy access for inspection
or change out of media. The baffle plates at the inlet remove a
large amount of solid particulate matter and entrained liquids which
are collected in the quiescent sump. The large sump area also provides
for slug control.
Use of the impingement baffle permits coalescer cartridges to function
more efficiently in the removal of microscopic solids and the fine
liquid entrainment.
|

Gas stream enter housing at point (A). Through the use of baffling
at point (B), impingement of solid particulate matter occurs. A certain
amount of liquid entrainment will drop out with solids and collect
in quiescent sump. Mist and minute solids will flow upwards and enter
coalescer cartridges, points (C). Oil mist particles will be coalesced
and solid particulate matter will be removed. Gas stream will flow
from inside-out. Coalesced droplets will be repelled by specially
treated separator cartridges, point (D). Liquid will fall to bottom.
An upper drain connection is available for this liquid to be removed
at point (H). Gas stream will flow through separator cartridges (D)
outside-in, and on through internal piping to outlet point (E). |
|

Body: Welded carbon steel construction
ASME Code, Section VIII, Div. 1, stamped and certified
Designed for 150 psi (10.5 kg/cm2) @ 250°F
Exterior: Prime coated
Swing bolt head closures
Head-Gasket: Buna-N o-ring other materials available
by request
Head lift furnished on 20" (508 mm) OD and larger
Inlet and outlet:
150#RF (ANSI) flanged
All other connections are 3000# NPT couplings |
|
|

Differential pressure gauge
Automatic drain valves
Liquid level gauge
|
| Top |
|