Facet
Vacuum Sewage Treatment Plants (VTP) for marine applications are
designed for the treatment of black water (coming from W.C., urinals
and hospital) and grey water (sinks, showers, laundry and galley)
generated onboard ships. This treatment includes the purification
and later disinfection of water in order to achieve a quality effluent
meeting all necessary requirements. These plants treat sewage biologically,
meaning they are of the active sludge, prolonged aeration, aerobic
type.
Facet VTP plants are built in a single steel module
to ease transportation and onboard installation. Inside this module
there are three specially designed chambers for aeration, settling
and disinfection. These chambers are oriented in such a way as to
guarantee correct operation and avoid sludge generation. Each chamber
has been provided with an access and inspection register.
Air diffusers are located in the aeration chamber,
and they produce both oxygenation and shaking of the liquid to be
treated. The unique design of the settling chamber causes the active
sludge inside it to separate from the effluent and automatically
recirculate to the aeration chamber. Both, the clarified liquid
and grey waters reach the disinfection chamber where a chlorine
solution is dispensed and metered in order to remove fecal coliform
bacteria. Once disinfection has taken place, the effluent is automatically
or manually discharged overboard or into a containment vessel.
What makes the VTP system unique is its built-in vacuum
system that transports black waters along the piping system to the
treatment plant. The vacuum in the circuit is achieved automatically
with the ejector and circulating pump.
Facet Sewage Treatment Plants VTP Series meet Marpol
Annex IV Requirements, 8(1)(b) and 9.1.1 Regulations, as well as
IMO Resolution MEPC-2(VI), CE Standards 96/98/EC and 98/85/EC; they
do not generate sludge that should be later discharged. The plants
are supplied completely assembled and tested so that their installation
onboard is very quick.

Meet IMO Resolution MEPC-2(VI)
Certified by the Maritime and Coastguard Agency and the CE
No sludge generation
No odor generation
Fully automatic operation driven by PLC
Protective epoxy coating both Inside and outside
Aeration system incorporates a blower, an air supply pipe,
bubble diffusers,
a filter and an air relief valve
Automatic sludge recirculation system
Access and inspection registers in every chamber
Electrical control panel, with IP-55 protection, including
operation synoptic panel
Vacuum ejectors
Circulating pumps
Stand-by blower
Stand-by discharge pump
Chlorine solution dosing pump
Grease trap
|